DS-i · Sludge separator
Sludge goes back into circulation and stops blocking the circuit.
DS-i is fitted on the return of a closed heating or cooling circuit and works on the same water, lap after lap.
- DN20 to DN200
- 1.2 to 510 m³/h
- −20 to 155 °C

The circuit it treats
A closed circuit: the same water, for years.
Heating water is never renewed. Whatever comes off the steel, the copper and the seals stays inside, and ends up settling in the emitters and in the boiler's heat exchanger.
Closed circuit: the water goes round. Every lap passes through the device before returning to the boiler.
No scheduled flushing
Nothing to drain or clean out each season.
No chemicals
Nothing is added to the circuit water.
Heating and cooling
It works the same on chilled and process water.
Sludge, up close
It does not come from outside: it is the circuit shedding itself.
The black sludge in a heating system is manufactured inside it, and every layer that settles is paid for in temperature and in consumption.
Magnetite
Black iron oxide
It forms as the steel in radiators and pipework corrodes. It is the bulk of the sludge and the part that clings hardest to the heat exchanger.
Copper
Metal particles
They come from the circuit itself and speed up steel corrosion wherever they settle.
1 mm
What a millimetre costs
A one millimetre layer on the heat exchanger is enough to make the boiler work harder for the same output temperature.
Low points
Where it collects
In underfloor manifolds, at the bottom of radiators, and in any run where the water slows down.
DS-i does not trap sludge in a canister: it returns it to circulation as fine particles and slows the corrosion that feeds it.
Where it goes
On the return, before the boiler.
Move through the cutaway: the device sits on the run where water comes back, and the numbered points are what stops collecting sludge.

- Position
- On the return, on the run before the boiler.
- Orientation
- Horizontal or vertical, in any mounting position.
- Works
- Two connectors. Only the cut run is drained.
The device, on the return run
It is fitted on the return, on the run before the boiler. Every litre in the circuit passes through it before being reheated, so one device covers the whole installation.
The device and what it protects
Circuit water passes through the device on every lap, so the treatment reaches every emitter without fitting anything to them.
Select a point on the cutaway to read what part it plays in the circuit.
Fitting it
It goes on the return and is never touched again.
No dosing, no canister to open and no seasonal service visit.
Isolate the return run
The existing valves are enough in most installations. There is no need to drain the whole circuit.
Fit the device the right way round
The arrow engraved on the body shows the direction of flow towards the boiler.
Refill and start up
No inhibitor, no scheduled flushing and nothing to check in the years that follow.
Full fitting instructions come with the technical sheet for each model.
Against the alternatives
Whatever a filter traps, somebody has to clean out.
There are three usual routes against sludge, and only one does not depend on somebody coming back every season.
DS-i · Sludge separator
DRAGEAU
Magnetic filter
Traps sludge in a canister
How it works
Consumables
Regular cleaning
Chemicals in the circuit
Pressure drop
If nobody checks it
The size
It is chosen by the diameter of the return.
Ten sizes, from a house circuit to a plant room. Pick the diameter and you will see the matching model, with its dimensions.
Nominal pipe diameter

Relative size across the range.
DN 25
DS-i25
- Connection
- 1″
- Max. flow
- 4.4 m³/h
- Length
- 119 mm
- Weight
- 1.3 kg
- Mounting
- Female thread
The size follows the pipe diameter, not the boiler output.
Questions about the sludge separator
What people ask before fitting it.
The return on your circuit has a diameter.
Tell us what it is and we will tell you the matching DS-i reference.
No obligation